Water filtration and water treatment systems need maintenance

Main­ten­ance of heat­ing and cool­ing net­works and water treat­ment

Reg­u­lar main­ten­ance keeps heat­ing, cool­ing and water treat­ment sys­tems reli­able and extends their ser­vice life. Faults are also repaired in time, before they turn into major renov­a­tions.

We always plan main­ten­ance to suit the site, wheth­er it is a hous­ing com­pany (res­id­en­tial prop­erty) or a demand­ing indus­tri­al pro­cess. Our ser­vices range from one-off ser­vi­cing to ongo­ing main­ten­ance con­tracts. We spe­cial­ise in flush­ing and filling demand­ing indus­tri­al sys­tems.

Request a quote

When does a sys­tem need ser­vi­cing?

VesiTekno at Korkeasaari
  • Cool­ing capa­city has dropped
  • The heat­ing net­work gives off heat poorly
  • Sludge, limes­cale or iron sed­i­ment has built up in the net­work
  • There is air in the sys­tem
  • The con­di­tion of the heat trans­fer flu­id has not been checked

Our main­ten­ance ser­vices

Net­work clean­ing
To clean heat­ing and cool­ing net­works, we use Eco­Boost® clean­ing solu­tion, which we man­u­fac­ture ourselves. It effect­ively removes impur­it­ies, limes­cale and sed­i­ment that have built up in the net­work, sig­ni­fic­antly improv­ing the system’s per­form­ance, energy effi­ciency and ser­vice life.


Fil­tra­tion:
We fil­ter heat­ing and cool­ing net­works with high-per­form­ance fil­tra­tion sys­tems, par­tic­u­larly in data centres, industry and oth­er demand­ing sites. Fil­tra­tion removes impur­it­ies, iron sed­i­ment and sus­pen­ded solids from the sys­tem without down­time, improv­ing heat trans­fer, oper­a­tion­al reli­ab­il­ity and energy effi­ciency.

Filling and vent­ing

After clean­ing and flush­ing, we fill the net­work with a heat trans­fer flu­id suited to the applic­a­tion. At the same time, we make sure the frost pro­tec­tion, pH  and flu­id qual­ity are cor­rect.

The sys­tem is ven­ted care­fully so that no air pock­ets remain in the net­work to impair flow, heat trans­fer and energy effi­ciency. A cor­rectly filled and ven­ted sys­tem works as designed, uses less energy and reduces the risk of mal­func­tions.

Bene­fits of filling and vent­ing:

  • Bet­ter heat and cold trans­fer
  • More even tem­per­at­ures across the net­work
  • Lower energy con­sump­tion
  • Few­er air prob­lems and less flow noise
  • Bet­ter oper­a­tion­al reli­ab­il­ity and a longer ser­vice life

Ves­iTekno handles filling, vent­ing and com­mis­sion­ing pro­fes­sion­ally so that the sys­tem reaches its best pos­sible per­form­ance straight after ser­vi­cing.

Fil­ter install­a­tion and ser­vi­cing

We install effect­ive fil­tra­tion solu­tions in net­works to keep the sys­tem clean after clean­ing, too. A cor­rectly chosen fil­ter reduces the build-up of impur­it­ies, improves heat trans­fer and extends the ser­vice life of the equip­ment.

  • Hei­fi-Top con­tinu­ously removes air, micro­bubbles and impur­it­ies from heat­ing and cool­ing net­works.
  • Fer­roclean effect­ively removes iron sed­i­ment and mag­netite using power­ful mag­nets. The solu­tion is par­tic­u­larly suited to large heat­ing and cool­ing net­works.
  • JUDO fil­ters also pro­tect domest­ic water and pro­cess water sys­tems from impur­it­ies, reduce the need for ser­vi­cing and improve sys­tem reli­ab­il­ity.

Fil­tra­tion is a cost-effect­ive way to keep the net­work clean, pre­vent new prob­lems and keep the sys­tem run­ning energy-effi­ciently well into the future.

Flu­id ana­lys­is and replace­ment
We check the con­di­tion of glycol and oth­er heat trans­fer flu­ids and replace them when needed. Samples are ana­lysed in an accred­ited labor­at­ory.

One-off ser­vice or main­ten­ance con­tract?

A one-off ser­vice suits you when the sys­tem has an acute prob­lem or you want it cleaned and restored to good con­di­tion in one go.

A main­ten­ance con­tract suits you when you want a long-term part­ner. We agree the ser­vice inter­val to suit the site, and you get ongo­ing peace of mind and pre­dict­able costs.

Bene­fits of main­ten­ance

Reg­u­lar main­ten­ance keeps heat­ing, cool­ing and domest­ic water sys­tems run­ning effi­ciently and without dis­rup­tion. Well-timed ser­vi­cing can pre­vent prob­lems before they turn into costly repairs.

  • The risk of unex­pec­ted faults and down­time is reduced.
  • Minor faults are detec­ted and repaired in time, which reduces repair costs.
  • A cor­rectly adjus­ted and ser­viced sys­tem uses less energy and works more effi­ciently.
  • The ser­vice life of pipe­work, equip­ment and heat trans­fer flu­ids is exten­ded.
  • Risks related to water qual­ity, cor­ro­sion and equip­ment dur­ab­il­ity are reduced.
  • Sys­tem reli­ab­il­ity and the qual­ity of indoor con­di­tions improve.

Pre­vent­ive main­ten­ance is one of the most cost-effect­ive ways to cut energy costs, extend equip­ment ser­vice life and keep a prop­erty run­ning without dis­rup­tion year after year.

VesiTekno van

How ser­vi­cing works

The ser­vi­cing pro­cess is designed to min­im­ise down­time. Not every step is needed at every site; the work is chosen based on the con­di­tion assess­ment.

01

Con­di­tion assess­ment and sampling

We assess the cur­rent state of the sys­tem and the con­di­tion of the heat trans­fer flu­id. Where needed, we take samples for labor­at­ory ana­lys­is.

02

Clean­ing

We clean the net­work with our own Eco­Boost® clean­ing solu­tion, which loosens sludge, limes­cale and mag­netite.

03

Flush­ing and fil­tra­tion

We flush the net­work and remove any remain­ing impur­it­ies, using side-stream or full-flow fil­tra­tion where needed.

04

Flu­id replace­ment or filling

We fill the sys­tem with a suit­able heat trans­fer flu­id and make sure the con­cen­tra­tion and freeze pro­tec­tion are cor­rect.

05

Vent­ing and optim­isa­tion

We vent the sys­tem, check its oper­a­tion and optim­ise the net­work for energy-effi­cient oper­a­tion.

06

Fil­ter install­a­tion

Where needed, we install Hei­fi-Top, Fer­roclean or JUDO fil­ters to keep the sys­tem clean in the future as well.

07

Report­ing and fol­low-up

We provide doc­u­ment­a­tion of the work car­ried out, togeth­er with recom­mend­a­tions for sys­tem main­ten­ance and future inspec­tions.

VesiTekno at Korkeasaari

Who is the ser­vice for?

We serve hous­ing com­pan­ies, prop­erty main­ten­ance com­pan­ies, con­struc­tion com­pan­ies and private indi­vidu­als, as well as demand­ing indus­tri­al sites. These include data centres, the paper and food indus­tries, the pro­cess industry, ice rinks and out­door rinks, and freez­ing plants.

Ice cream fact­ory

Limes­cale depos­its had built up in the water pipe­work of the refri­ger­a­tion plant’s con­dens­ers, impair­ing heat trans­fer and increas­ing the system’s ser­vi­cing needs. Ves­iTekno sup­plied and installed sev­er­al Vul­can water treat­ment sys­tems, which change the crys­tal struc­ture of limes­cale using an elec­tro­phys­ic­al meth­od. As a res­ult, limes­cale does not adhere to the sur­faces of pipe­work and equip­ment in the same way as in untreated water.

The solu­tion brought the form­a­tion of limes­cale depos­its under con­trol, kept heat trans­fer effi­cient and improved sys­tem reli­ab­il­ity.

Cus­tom­er bene­fits:

  • Few­er limes­cale depos­its in pipe­work and heat exchangers
  • Bet­ter heat trans­fer and energy effi­ciency
  • Less need for ser­vi­cing and clean­ing
  • Longer equip­ment ser­vice life
  • Bet­ter reli­ab­il­ity in a crit­ic­al pro­duc­tion envir­on­ment

Vul­can sys­tems offer a chem­ic­al-free way to pre­vent limes­cale prob­lems and main­tain sys­tem per­form­ance over the long term.

Vesitekno palvelut

Amazo­nia house at Korkeas­aari

Ves­iTekno car­ried out the clean­ing and mod­ern­isa­tion of the building’s heat­ing net­works and provides ongo­ing main­ten­ance. Pre­vent­ive main­ten­ance has ensured reli­able sys­tem oper­a­tion, good water qual­ity and a long ser­vice life, and reduced the risk of mal­func­tions and repairs.

See all ref­er­ences

Fre­quently asked ques­tions

Yes. We also ser­vice, inspect and refur­bish sys­tems sup­plied and installed by oth­ers. Our spe­cial­ists can help regard­less of who was respons­ible for the ori­gin­al install­a­tion or com­mis­sion­ing.

Our ser­vices cov­er, for example:

  • Heat­ing and cool­ing net­works
  • Glycol and oth­er heat trans­fer flu­id sys­tems
  • Domest­ic water and pro­cess water sys­tems
  • Fil­ter and water treat­ment equip­ment

We are often called in to solve per­form­ance, water qual­ity or energy effi­ciency prob­lems years after the ori­gin­al install­a­tion. We start by assess­ing the cur­rent state of the sys­tem and choose the right meas­ures on that basis.

Yes. Our installers were trained at the JUDO fact­ory in Ger­many and spe­cial­ise in installing, ser­vi­cing and repair­ing JUDO fil­ters. Thanks to this train­ing, we are pro­fi­cient in com­mis­sion­ing, ser­vi­cing and fault dia­gnostics for the equip­ment.

For JUDO equip­ment, we provide:

  • Ser­vi­cing and peri­od­ic inspec­tions
  • Fault repairs and refur­bish­ment
  • Spare parts and wear parts avail­able quickly
  • Com­mis­sion­ing and tech­nic­al sup­port
  • Fil­ter solu­tions for domest­ic water and pro­cess water sys­tems

This keeps JUDO equip­ment in work­ing order through­out its life cycle.

Heat­ing, cool­ing and domest­ic water sys­tems should have a con­di­tion inspec­tion at least once a year so that any prob­lems are detec­ted before they cause dis­rup­tion or extra costs.


The actu­al ser­vice inter­val depends on the site’s use, the size of the sys­tem and the oper­at­ing con­di­tions. In data centres, indus­tri­al sites and oth­er crit­ic­al sys­tems, for example, inspec­tions may be needed more often than once a year.


Reg­u­lar main­ten­ance helps to:
pre­vent unex­pec­ted down­time
reduce energy con­sump­tion
extend equip­ment ser­vice life
main­tain the qual­ity of water and heat trans­fer flu­ids
reduce repair and ser­vi­cing costs


Ves­iTekno draws up an indi­vidu­al ser­vi­cing pro­gramme for each site, based on the system’s con­di­tion, its use and the customer’s needs.

Clean­ing a heat­ing or cool­ing net­work typ­ic­ally takes from a few days to sev­er­al weeks, depend­ing on the size of the site and the con­di­tion of the net­work. The net­work can be flushed, filtered, ven­ted and optim­ised at the same time, so the whole sys­tem is put in order in one go.


How ser­vi­cing affects sys­tem oper­a­tion depends on the work:

No down­time: flu­id ana­lyses, con­di­tion inspec­tions and side-stream fil­tra­tion can often be done while the sys­tem is in nor­mal use.

Short inter­rup­tion: at many sites, fil­ters and sep­ar­at­ors can be installed with a short inter­rup­tion.

Par­tial or full shut­down: net­work clean­ing, flush­ing and heat trans­fer flu­id replace­ment usu­ally require the sys­tem to be shut down for the dur­a­tion of the work.

We always plan and sched­ule the work around how the site is used, so that the impact on the building’s users is kept to a min­im­um.

VesiTekno at Korkeasaari

Contact us or request a quote

I am interested in…